Hydraforce SP10-57C-0-N-00 Electro-Proportional Controls, 3-Position 5-Way, Closed Center, Non-Vented

Price:

164.99 $


Replacement Spool Valve for  Hydraulic Multipliers
Replacement Spool Valve for Hydraulic Multipliers
69.95 $
69.95 $
Monoblock Hydraulic Directional Control Valve,1 Spool,11 GPM
Monoblock Hydraulic Directional Control Valve,1 Spool,11 GPM
99.95 $
99.95 $

Hydraforce SP10-57C-0-N-00 Electro-Proportional Controls, 3-Position 5-Way, Closed Center, Non-Vented

https://afdportal.com/web/image/product.template/15931/image_1920?unique=0dd4bf3

Free Shipping!

164.99 $ 164.99 CAD 164.99 $

164.99

Not Available For Sale


  • Weight1

This combination does not exist.


SKU: :
SP10-57C-0-N-00
Categories: :
10 Series (5/8")
Share :
100% original guarantee
Return within 30days
Free delivery on all orders

Hydraforce SP10-57C-0-N-00 Electro-Proportional Controls, 3-Position 5-Way, Closed Center, Non-Vented

SKU: SP10-57C-0-N-00

Hydraforce Part Number: SP10-57C-0-N-00

Seal Kit: SK10-5X-MMMM X = seal option

This valve is a direct – acting 3 position, 5 port proportional directional control. With port 1 as a load sense port it is a screw in cartridge type for use with general purpose hydraulic fluids.

  • Continuous-duty rated solenoid.
  • Hardened precision spool and cage for long life.
  • Optional coil voltages and terminations.
  • Manual override option.
  • Optional waterproof E-Coils rated up to IP69K.
  • Cartridges are voltage interchangeable.
  • Industry-common cavity.

Specifications

Pressure rating:

  • 250 bar (3625 psi)

Flow rating:

  • 22.7 lpm (6.0 gpm) SP10-57C
  • 18.9 lpm (5.0 gpm) SP10-57CX

Maximum internal leakage:

  • 246 ml/min (15 in³/min) SP10-57C max at 207 bar (3000 psi)
  • 164 ml/min (10 in³/min) SP10-57CX max at 207 bar (3000 psi)

Operating fluid temperature:

  • -40 to 100 °C (-40 to 212 °F) With buna N seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With polyurethane seals

Storage temperature:

  • -40 to 70 °C (-40 to 158 °F)

Ambient temperature:

  • -40 to 70 °C (-40 to 158 °F)

Fluids:

  • Mineral based or synthetic hydraulic fluid with lubricating properties

Fluid viscosity range:

  • 10 to 420 cSt

Maximum operating contamination level:

  • 20/18/14 per ISO 4406

Cavity:

  • VC10-5
  • 10-size-5-way Cavities

Cartridge installation torque:

  • 32.5 to 35.3 N-m (24 to 26 ft-lb)

Maximum allowable torque:

  • 61 N-m (45 ft-lb)

Coil nut torque:

  • 6.8 to 9.5 N-m (5 to 7 ft-lb)

Orientation restriction:

  • None


Weight1 aaa1 lbs