HE Medium Pressure Spin-On Filter Elements
FOR USE WITH HF SERIES FILTER HEADS
Our pressure filters provide in-line system protection for sensitive system components like servo valves, pressure Spin-on filters are used as process and safety filters to protect individual pumps, valves or the entire hydraulic circuit from contamination as measured per ISO 4406.
Categories: :
Hydraulic Spin-On FiltersApplications
- Suction filters
- On the return circuit, for mounting on the line or on the tank cover
- In-line for low and medium pressure applications
- mowers
- tow trucks
- truck-mounted aerial lifts and cranes
- pavers
- compactors
- wood splitters and chippers
- trenchers
- utility terrain vehicles (UTVs).
Parts and Detail
Part Number | Particle Size | Nominal Rating | Absolute Rating | Can Color / Imprint | Media Type* | Free Water Absorption | Overall Height |
HE03 | 3 Micron | ß<4µ(c) = 2 | ß7µ(c) = 75 | White / Green | Cellulose | 5.9” | |
HE03AZL | 3 Micron | ß5µ(c) = 2 | ß24µ(c) = 75 | White / Orange | Aqua-Zorb | 7.2 oz | 8.0” |
HE10 | 10 Micron | ß11µ(c) = 2 | ß25µ(c) = 75 | White / Red | Cellulose | 5.9” | |
HE10L | 10 Micron | ß<4µ(c) = 2 | ß19µ(c) = 75 | White / Red | Cellulose | 8.0” |
*Glass media is available. Contact factory for quote.
Application Data
- Reference:
- ßXµ(c) = 2 represents 50% efficiency at Particle Size (Nominal Rating)
- ßXµ(c) = 75 represents 98.7% efficiency at Particle Size (Absolute Rating)
- Buna-N gasket standard. Fluorocarbon gasket optional, consult factory.
- Suitable for petroleum-based fluids. Consult factory for synthetic fluids.
- Caution: Do not use HE Series filter elements on internal combustion engines.
- Aqua-Zorb filter medias absorb and retain free water. Any absorbed water cannot be liberated from the Aqua-Zorb media. As the element becomes saturated with water, the Aqua-Zorb media continues to swell, and will ultimately curtail flow through the filter. Not for use with water-glycols.
Diameter | 3.7” |
Mounting Thread | 1 1/2” – 16 UN |
Pressure | 300 PSI Max. Operating |
Pmax Cellulose | 50 PSID |
Pmax Z-Glass | 80 PSID |
Temperature | Up to +250°F Operating |
APPLICATION | Petroleum-based fluids |