Hydraforce EP10-S35-0-N-40 Piloted Spool-Type Logic Element Valve

Price:

59.95 $


Replacement Spool Valve for  Hydraulic Multipliers
Replacement Spool Valve for Hydraulic Multipliers
69.95 $
69.95 $
Monoblock Hydraulic Directional Control Valve,1 Spool,11 GPM
Monoblock Hydraulic Directional Control Valve,1 Spool,11 GPM
99.95 $
99.95 $

Hydraforce EP10-S35-0-N-40 Piloted Spool-Type Logic Element Valve

https://afdportal.com/web/image/product.template/15925/image_1920?unique=0dd4bf3

Free Shipping!

59.95 $ 59.95 CAD 59.95 $

59.95

Not Available For Sale


  • Weight

This combination does not exist.


SKU: :
EP10-S35-0-N-40
Categories: :
10 Series (5/8")
Share :
100% original guarantee
Return within 30days
Fast delivery 

Hydraforce EP10-S35-0-N-40 Directional Controls – Logic Element – Pilot to Close

SKU: EP10-S35-0-N-40

Hydraforce Part Number: EP10-S35-0-N-40

Seal Kit: SK16-S3X-MM Note: X = seal option

The EP08-35 is a screw-in, cartridge style, spool type, hydraulic directional element.

The EP08-35 is a spring-biased blocking valve, which will open port 1 to 2 when pressure at port 1 exceeds the cumulative pressure at port 3 and the bias spring pressure value. With no pressure at port 3 flow will be allowed from port 1 to 2 once the bias spring force is overcome with pressure at port 1.

  • Multiple function/application potential.
  • Low pressure drop.
  • Compact size.
  • Industry-common cavity.

Specification

Pressure rating:

  • 345 bar (5000 psi)

Flow rating:

  • See performance graph

Maximum internal leakage:

  • 164 ml/min (10 in³/min) At 207 bar (3000 psi)

Operating fluid temperature:

  • -40 to 100 °C (-40 to 212 °F) With buna N seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With polyurethane seals

Storage temperature:

  • -40 to 70 °C (-40 to 160 °F)

Ambient temperature:

  • -40 to 90 °C (-40 to 194 °F)

Fluids:

  • Mineral based or synthetic hydraulic fluid with lubricating properties

Fluid viscosity range:

  • 4 to 420 cSt

Maximum operating contamination level:

  • 20/18/14 per ISO 4406

Cavity:

  • VC08-3
  • 08-size-3-way Cavities

Cartridge installation torque:

  • 25.8 to 28.5 N-m (19 to 21 ft-lb)

Maximum allowable torque:

  • 54.2 N-m (40 ft-lb)

Orientation restriction:

  • None


Weight 0.63 lbs